The Lovibond® SD 70 is a portable conductivity meter designed for convenient and reliable conductivity measurement in water-testing and laboratory applications.

The meter automatically switches between µS and mS measurement ranges and provides a conductivity range up to 20.00 mS. It supports automatic one- or two-point calibration using 1413 µS and/or 12.88 mS conductivity standards, as well as manual calibration with adjustable values.

An integrated temperature measurement function provides 0.1°C resolution, selectable °C/°F units, and automatic temperature compensation at 2%/°C. The meter also includes date and time display, 25 measurement storage locations, a 22 × 22 mm LCD with green-yellow backlight, automatic shut-off after 8 minutes of inactivity, and a low-battery indicator.

The device operates using two AAA 1.5 V batteries and provides more than 100 hours of continuous operation when the backlight is not used. The replaceable electrode design helps simplify maintenance and extend practical service use. 

Features
  • Conductivity measurement from µS range up to 20.00 mS.
  • Automatic switching between µS and mS ranges.
  • Automatic one- or two-point calibration.
  • Manual calibration up to two points.
  • Supports 1413 µS and 12.88 mS calibration standards.
  • Conductivity accuracy: ±3% FS.
  • Automatic temperature compensation: 2%/°C.
  • Temperature display with °C/°F selection.
  • 25 measurement memory locations.
  • Date and time display.
  • 22 × 22 mm backlit LCD.
  • Automatic shut-off after 8 minutes of inactivity.
  • Replaceable electrode.
  • Low-battery indicator.
  • Powered by 2 × AAA 1.5 V batteries.
  • More than 100 hours of continuous battery operation without backlight.
Intended Use
  • Intended for measuring the electrical conductivity of water and aqueous samples.
  • Suitable for water-testing, laboratory, quality-control, and related conductivity measurement applications.
  • Provides simultaneous conductivity and temperature-related measurement functions.
Instructions
  1. Remove the protective cap from the electrode.
  2. Rinse the electrode with distilled water before measurement.
  3. Immerse the electrode in the sample, without immersing the meter above the sealing ring.
  4. Switch on the device and allow the conductivity reading to stabilize.
  5. The measurement is displayed automatically.
  6. Press the measurement key briefly to freeze or release the displayed result when required.
  7. Press and hold the save key for approximately 3 seconds to store the measurement.
  8. Rinse the electrode with distilled water after measurement.
  9. Calibrate the meter periodically using the appropriate conductivity standard.
  10. Replace the protective cap after cleaning and before storage.
What's included
  • 1 × Lovibond® SD 70 CON Conductivity Meter
  • 1 × Carrying Case
  • 1 × Lovibond® Lanyard
  • 1 × Instruction Manual
  • 1 × Certificate of Compliance
Precautions
  • Do not immerse the meter above the electrode sealing ring.
  • Rinse the electrode with distilled water before and after measurements.
  • Use suitable conductivity calibration solutions for calibration.
  • Do not use the instrument outside its specified temperature or conductivity measuring range.
  • Replace the electrode if it is damaged or produces persistent electrode-related errors.
  • Keep the battery compartment dry.
  • Remove or replace depleted batteries promptly.
  • Do not dispose of used batteries with normal household waste; follow applicable battery-disposal requirements. 
How To Store
  • Clean and rinse the electrode with distilled water after use.
  • Refit the protective cap before storage.
  • Store the meter clean and dry.
  • Protect the instrument from moisture, mechanical damage, and improper handling.
  • If stored for an extended period, check the batteries before reuse.
Certified By
  • ISO 9001 Certified Quality Management System
Items shipped may differ slightly from the images shown

Specifications

Reference Code MLBLE-0001
Category Lab Equipment & Analyzers
PCS/UOM 1 PC/Each
Origin Made in China
Brand Lovibond®

Measurement Type

Conductivity

Operating Temperature Range

0–60°C

Conductivity Range

1–1999 µS / 2.00–20.00 mS

Automatic Range Switching

µS / mS

Conductivity Resolution

1 µS up to 1999 µS / 0.01 mS from 2.00–20.00 mS

Conductivity Accuracy

±3% FS

Automatic Calibration

1 or 2 Point

Automatic Calibration Standards

1413 µS and/or 12.88 mS

Manual Calibration

Up to 2 Points

Manual Adjustment Range

±50%

Temperature Resolution

0.1°C

Temperature Accuracy

±1°C

Temperature Unit

°C / °F

Automatic Temperature Compensation

2%/°C

Data Memory

25 Storage Locations

Date & Time Display

Yes

Clock Format

12-hour / 24-hour selectable

Display

22 × 22 mm LCD

Backlight

Green-Yellow

Automatic Shut-Off

After 8 Minutes of Inactivity

Power Supply

2 × AAA, 1.5 V

Battery Life

>100 Hours Continuous Use Without Backlight

Low Battery Indicator

Yes

Electrode

Replaceable

Calibration Modes

Automatic / Manual

Measurement Hold

Yes

Saved Data Viewing

Yes

Saved Data Deletion

Yes